Re: polyclt shutdown

From: Duane Wessels (wessels@measurement-factory.com)
Date: Fri Apr 13 2001 - 16:19:46 MDT


On Fri, 13 Apr 2001, Lynn Scott wrote:

> Dear Sirs,
>
> I previous inquired of Alex on using the the --notify option to signal
> my process when Web Polygraph was complete. Alex mentioned that if
> properly configured, Polygraph processes quit when the test is over. In
> doing some testing, I am running polymix-1 on a single workstation with
> a very small duration expirement.
>
> // experiment duration
> time ExpDur = 1min
>
> After the tests complete the server process (polysrv) shutsdown properly
>
> 002.22| got 698 xactions and 0 errors
> 002.22| shutdown reason: all 4 phases met their goals
>
> However, the client process continues to run.
>
> 002.35| i-cool 870 3.79 45001 100.00 18 28
> 002.43| i-cool 870 0.20 -1 -1.00 1 27
> 002.52| i-cool 870 3.19 -1 -1.00 16 11
> 002.60| i-cool 870 2.00 -1 -1.00 10 1
> 002.69| i-cool 870 0.00 -1 -1.00 0 1
> 002.77| i-cool 870 0.00 -1 -1.00 0 1
> 002.85| i-cool 870 0.20 -1 -1.00 1 0
>
> How do I properly configure so that both will shutdown?

You might have to wait just a bit longer. I think the cool phase
is hard-wired at one minute. Also the cool phase might not exit
as long as there are outstanding requests (the last column).